Details:
GT06 is a Mini intelligent GPS Vehicle positioning terminal. It combines the GSM wireless communication technology and GPS positioning system technology,terminals using industrial-grade highly integrated design,intelligent power-saving and passive drift suppression,installation is simple,connect the power supply to start work immediately,wide inpute voltage range,wide applicable to all types of cars,motor cycles,electric cars,ships,etc., can provide all-weather,real-time vehicle positioning function,with global positioning service platform,you can achieve remote vehicle management.
Device feature
Working Based on existing GSM/GPRS network and GPS satellites, this product can locate and monitor any remote targets by SMS or internet.
Overview of the characteristics:
1.GPS position.
2.GSM 850/900/1800/1900MHZ.
3.With Shock sensor.
4.300Mah Battery inside, Power-Cut alarm.
5.Auto set APN.
6.Voltage 9-50V.
7.SOS alarm.
8.Voice Surveillance.
9.ACC detect.
1. Specification
1).GSM:850/900/1800/1900MHZ
2).GPRS: Class12, TCP/IP
3).Working Voltage:9-50V DC
4).Working current:22mA (12VDC)
5).Working current:12mA (24VDC)
6).GPS locating time:
Cold start:38s(Open sky)
Warm start:32s
Hot start:2s(Open sky)
7).GPS Precision:10m(2D RM)
8).Working temperature:-20 Celsius~+70 Celsius
9).Working humidity:20%~80%RH
10).Measurement:98(L)×52(W)×16.5(H)mm
2.Accessories
SOS wire
Power wire
l
Microphone
Relay
3.Platform:
The platform free use for 1 year.
4.Wire defined
5.Device wiring
6. SMS Commands instruction
1)Administrator Number
|
Text command
|
Parameter
|
Sample
|
CENTER Add
|
710#number#
711#number#
|
710#13500135000#
711#13800138000#
|
CENTER Del
|
D01#
D02#
|
D01#
D02#
|
Command Description
|
1)Center number can control the oil and power and resume factory settings
2) Center number can receive the call and text of vibration alarm and over speeding alarm.
3) SIM must display the income call number to control oil and power.
4) Only one number can be center number.
5) Change center number must resend the command.
6)Add new center number by CETNER,A, and delete by CENTER,D
|
Command Feedback
|
Successful Setting:Add admin account 1 OK!
|
2) View Administrator Number
|
Text command
|
Parameter
|
Sample
|
View
|
901#
|
901#
|
Command Description
|
This directive is used to view Device Manager number.
|
Command Feedback
|
Successful Setting:Admin1:
Admin2:
|
|
|
|
|
3)Authorized Number Set
|
Text command
|
Parameter
|
Sample
|
Authorized Add
|
101# number #
102# number #
103# number #
|
1:101#13800138000#
2:102#12345678912#
3:103#12345678912#
|
Authorized Del
|
D11#
D12#
D13#
|
D11#
D12#
D13#
|
Command Description
|
1) Authorization number for SMS control oil.
2) only three numbers to set the authorization number
3) change the authorization number needs to delete the previous number
|
Command Feedback
|
Successful Setting:Add Authorization account 1 OK!
|
4) View Authorized Number
|
Text command
|
Parameter
|
Sample
|
View authorized
|
C10#
|
C10#
|
Command Description
|
This directive is used to view the equipment authorization number
|
Command Feedback
|
Successful Setting:
Authorization 1:
Authorization 2:
Authorization 3:
|
5)APN Setting
|
Text command
|
Parameter
|
Sample
|
APN Setting
|
APN#username#password]
|
1:APN#intenet#123#123#
2: APN#internet#
|
Command Description
|
APN differs according to the local telecom operators.
For example:APN request password,please refer to Sample 1,and Sample 2 for no password.
|
Command Feedback
|
Successful Setting:SET APN OK!
|
6) Set / View Server
|
Text command
|
Parameter
|
Sample
|
SERVER Parameter
|
803#SERVER # port#
|
803#222.217.240.243#8011#
|
View SERVER
|
CIP#
|
1)CIP#
|
Command Description
|
Change the IP and port when move to a new server
port:10~65535
1 is domain and 0 is IP;
|
Command Feedback
|
Successful Setting:set IP OK!
|
7)Moving Time Interval
|
Text command
|
Parameter
|
Sample
|
TIMEER Parameter setting
|
730#uploading interval#
|
730#20#
|
Command Description
|
Time scope:0,10~60 seconds; 0,no data uploading;
10~60,means time interval;the default value is 15 seconds!
|
Command Feedback
|
Successful Setting:SET TIMER OK!
|
8)Static Time Interval
|
Text command
|
Parameter
|
Sample
|
STATIC
|
SUP# time interval#
|
SUP#5#
|
Command Description
|
Timescope:1~60 seconds;The device has
3D transmission and the default time interval are 5 minutes.
|
Command Feedback
|
Successful Setting:SET STATIC TIME OK!
|
9) Cancel the continuous upload
|
Text command
|
Parameter
|
Sample
|
NUP
|
NUP#
|
NUP#
|
Command
Description
|
This command is used to cancel sending data to the platform
If need again to restore the upload , you need to send TIMEER Parameter setting.
|
Command Feedback
|
SET OK!
|
10)Power-Cut
|
Text command
|
Parameter
|
Sample
|
RELAYParameter1
|
222#
|
222# cut off oil and power
|
RELAYParameter2
|
333#
|
333# recover oil and power
|
Command Description
|
1)RELAY control the start and closeness of the relay
2) Only the center number can operate.
3)the device only cut off the oil circuit on the condition of the driving speed below 20KM/H or in static state.
4)When send the command, the device will reply “please waiting “When the vehicle speed is over 20KM/H, the device will cut off the oil or the power when the speed below 20KM/H.
|
Command Feedback
|
Successful Setting:Fuel cut has already been completed OK!
|
11)GMT
|
Text command
|
Parameter
|
Sample
|
GMT
|
801#location, time#
|
801#E8#
|
Command Description
|
The default time zone is Beijing time. If time zone need revised, please operate according to the above command.
|
Command Feedback
|
Successful Setting:Set time zone ok!
|
12)Vibration Sensitivity
|
Text command
|
Parameter
|
Sample
|
VIBRATION Parameter
|
123#2#,alarming way#
|
1) 123#2#3#
|
Set into vibration alarm time
|
V123#2#
|
1) V123#2#
2) V123#1#
|
Cancel vibration alarm
|
456#
|
456#
|
Command Description
|
the sensitivity value of the vibration is from 1 to 5,1is the most sensitive and o is close. Alarming ways: 1, calling 2, texting, 3 calling and texting.
Must set the center number and receiving number.
|
Command Feedback
|
set vibration alarm level,OK!
|
13)Speeding
|
Text command
|
Parameter
|
Sample
|
SPEEDING Parameter
|
SSA#120# alarming way#
|
1)SPEEDING,120,3#
2)SPEEDING,120#
|
Command Description
|
The speed scope is form 60-220, if the speed is no this cope, the alarm is off.
Alarming :1, calling 2, texting, 3 calling and texting.
Must set the center number and receiving number.
|
Command Feedback
|
Successful Setting:set speeding alarm,OK!
|
14)Reset
|
Text command
|
Parameter
|
Sample
|
RESET
|
930#
|
930#
|
Command Description
|
Reset the device
|
Command Feedback
|
Successful Setting:Reset system, ok!
|
15)Factory
|
Text command
|
Parameter
|
Sample
|
Parameter
|
940#
|
940#
|
Command Description
|
Restore the factory setting
Only center number can initial this function
Factory setting will recover to the original setting
|
Command Feedback
|
Successful Setting:FACTORY OK!
|
16)Language Setting
|
Text command
|
Parameter
|
Sample
|
LANG Parameter
|
LANG1#
LANG0#
|
LANG1# 1:CHINESE,
LANG0#:ENGLISH
|
Command Description
|
;When check the location, it will reply the Chinese location in Chinese language setting; while reply the URL link when in English language setting.
|
Command Feedback
|
Successful Setting:SET LANG OK!
|
17)Position
|
Text command
|
Parameter
|
Sample
|
WHERE
|
988#
|
988#
|
Command Description
|
Check the longitude and altitude and other information of the device
|
Command Feedback
|
Reply with longitude and altitude, speed and IMEL.
|
19)Version
|
Text command
|
Parameter
|
Sample
|
VERSION
|
V00#
|
V00#
|
Command Description
|
The command is to check the software version
|
Command Feedback
|
VERSION:Xxxx
BUILD:2012-07-05 10:12
|
20)Param Check
|
Text command
|
Parameter
|
Sample
|
PARAM
|
886#
|
886#
|
Command Description
|
The command is to check the settings and the default parameter.
|
Command Feedback
|
IMEI:351190012535936
APN : cmnet
IP:IP and port
TIMER: moving uploading interval
STATIC: static uploading interval
CENTER: center number
LANG: language(CN/EN)
GMT: time zone (E/W8)
|
21)Status Check
|
Text command
|
Parameter
|
Sample
|
STATUS
|
902#
|
902#
|
Command Description
|
The command is designed for checking the device’s working status.
|
Command Feedback
|
External power:ON/OFF
GSM Signal:HIGH/MIDDLE/LOW
GPS:FIXED/UNFIXED
RELAYER:DISABLE/ENABLE
Vibrate Warning:ON/OFF
Pause:ON/OFF
|
22) Monitor (Voice Surveillance)
|
Text command
|
Parameter
|
Sample
|
SSS#
|
SSS#
|
SSS#
|
Command Description
|
Using Command Send this command to the tracker’s number, the tracker will call back to admin number.
|
Command Feedback
|
|
|